(12) METHODS FOR CONTINUITY TESTS
In making a continuity test whether it be for the Theremin assembly or the S. P. U., the following procedure is recommended:
Disconnect the cable connecting the socket power unit to the Theremin assembly, the loudspeaker, and the A.C. supply cord at its outlet.
A pair of headphones, with at least 41/2 volts in series, or preferably a voltmeter with sufficient voltage to give a full scale deflection when connected across the battery terminals, should be used in making these tests, for example, a 0-50 volt meter with a 4,5volt “B” battery. The Radiotron socket contacts, numbers and lugs used in these tests are shown in Figure 6. The Theremin continuity wiring diagram is illustrated in Figure 8, the S. P. U. terminal numbers are shown in Figure 7.
Test leads should be of the flexible insulated type with partially insulated testing tips, so that false readings will not be obtained through contact with the hands. Similarly the hand should not touch the chassis or component parts.
The contacts of the test equipment should be placed across the terminals or leads indicated in the following test table under the column marked “Terminals.” If the results are negative the cause of such negative effect will be found in the last column under the heading, “Incorrect Effect Caused By.” The second column indicates the approximate correct resistance in ohms of most of the circuits tested.
(13) S.P.U. CONTINUITY TESTS
Remove UX-280 Radiotron and Disconnect Cable -Refer to Figure 8
Test Terminals | Correct Effect | Incorrect Effect | |
Indication | Caused by | ||
Terminal No. 1 to filament of rectifier socket | 1000 ohms | Open | Open reactor |
No. 1 to No. 7 | 22,000 ohms | Shorted | Shorted filter condenser |
No. 2 to one loudspeaker pin jack | Closed | Open | Open lead |
No. 2 to other pin jack | Open | Closed | Shorted 0,02 condenser |
No. 3 to No. 4 | Shorted | Open | Open connection |
No. 3 to No. 1 | 2500 ohms | 14,000 ohms 2250 ohms | Open 2250-ohms resistor Open 14,300-ohm resistor |
No. 3 to No. 6 | 20,000 ohms | Open Shorted | Open 20,000-ohm resistor Shorted 0.5 mfd. condenser |
No. 5 to No. 8 or 9 | 13 ohms | 25 to 30 ohms | Open power transformer winding |
No. 6 to No. 10 or 11 | 13 ohms | 25 to 30 ohms | Open power transformer winding |
No. 7 to either plate contact of rectifier socket | 190 ohms | Open | Open connection or open winding in power transformer |
No. 8 to No. 9 | Shorted | 60 ohms | Open 5-volt filament winding |
No. 10 to No. 11 | Shorted | 60 ohms | Open 2.5-volt filament winding |
Across contacts of auxiliary power receptacle | 3 to 6 ohms | Open | Open primary of power transformer or open 110-220-volt switch |
Across blades of AC input plug with auxiliary receptacle shorted | Closed | Open | Open operating switch, open lead or connection |
From either contact of auxiliary receptacle to frame | Open | Closed | Grounded primary in power transformer |